    Active Repeater

CR244

 

 

Do you have 3-phase power? Then you can use the CR244 coupler/repeater to allow A10/X10 signals to pass through on all of the phases. As well as coupling the phases, the CR244 will add to the reliability of your X10/A10 system.

 

The CR244 repeats A10/X10 power line carrier transmission signals on all phases of a 230V/400V 50Hz system. The signal will also be amplified and re-sent on the phase where the signal was original received from.

 

 

 

 

Features

  • Repeats both the signals from MicroModules as well as regular A10/X10 transmitters.

  • Pre installed in IP54 plastic cabinet: designed to install in the main distribution box.

  • Status LEDs on cover.

  • Can also be used as signal repeater in a one phase installation.

  • Calculates signals on 2nd and 3rd phase from the 1 phase compatible signals of MicroModules.

  • Repeats the 3 phase compatible signals of regular X10 transmitters.

  • Two way

  • A10 technology means signals repeated are of higher voltage to normal X10 signals, giving extra reliability to your system.

  • Fuse protected.

 

 Applications

  • Use MicroModules in a 3-phase installation.

  • Signal amplification of X10 signals on all 3 phases.

 

LED Display

POWER          CR244 is active

READY           Ready for receiving data

RECEIVE        Receiving data

TRANSMIT     Transmitting data

ERROR           Error in data

 

 

Installation

Wiring:          Brown           L1 Phase 1 + Power (should always be connected to 230V)

Black            L2 Phase 2

Black            L3 Phase 3

Blue              N Neutral

Yellow/Green  Earth Connection (not connected inside the repeater)

 

The CR244 should be installed behind a fuse (e.g. 10A). Normally, the best location to hook up the CR244 is behind a 3-phase master switch of a 400V power group (e.g. cooking or heating group). When earth leakage switches are installed, the CR244 should be installed before the earth leakage switches to prevent the unwanted trigger of the earth leak switches. When you use a 3-phase earth leakage switch with one neutral connection, you will be able to connect the CR244 behind it. 

Note: Installation to be performed by a licensed electrical contractor.